<Articles><Article><Journal><PublisherName></PublisherName><JournalTitle>Journal of Diabetes and Metabolic Disorders</JournalTitle><Volume>2</Volume><Issue>0</Issue></Journal><ArticleTitle>THE BIOLOGICAL EFFECTS OF MAGNETIC FIELDS: FIELD EFFECT ON BLOOD GLUCOSE IN LABORATORY MICE.</ArticleTitle><FirstPage>37</FirstPage><LastPage>37</LastPage><AuthorList><Author><FirstName>Mehrshad</FirstName><LastName>ABBASSI</LastName></Author><Author><FirstName>Manouchehr</FirstName><LastName>NAKHJAVANI</LastName></Author></AuthorList><History><PubDate PubStatus="received"><Year>2015</Year><Month>10</Month><Day>05</Day></PubDate></History><Abstract>Background: There are disputed reports of the beneficial effects of magnetic fields on glucose homeostasis.&amp;nbsp; Continuing from our previous work, we studied the effect of a constant magnetic field on blood glucose and weight gain in laboratory mice.
Methods: 28 young, female bALB/c mice were randomly allocated into four groups A, B, C and D.&amp;nbsp; Group A were placed in a constant magnetic field for 20 days, group B for 20 days in a 'placebo' field, group C for 10 days in a constant magnetic field, after which the field was removed, and group D for 10 days in a 'placebo' field, which was then removed the remaining 10 days of the study.&amp;nbsp; The induction force of the magnetic field was 500 gauss, and was generated by two natural magnet bars.&amp;nbsp; 'Placebo' fields were created by two identical looking bars of granite.&amp;nbsp; The mice were weighed daily and had their blood glucose measured at the end of the 20-day study.
Results: Weight gain was similar in the four groups.&amp;nbsp; Blood glucose was significantly lower in group C mice than in groups B and D mice.&amp;nbsp; No other significant difference in blood glucose between the groups was detected.
Conclusion: Even though blood glucose remained unchanged whilst mice are inside a magnetic field, the blood glucose of mice 10 days after field removal is lower than in mice that had never been inside a magnetic field.</Abstract><web_url>https://jdmd.tums.ac.ir/index.php/jdmd/article/view/37</web_url></Article></Articles>